HC series pull-out tester for anchors, rebars and expansion bolts, also for on-site tests of glass curtain wall fixings.
Overview
The HC series HC Series Anchor Bolt Pull-out Tester is used for anchoring force testing of various anchors, steel bars and expansion bolts, and can also perform on-site pull-out testing of glass curtain walls. It features Chinese/English setting menu and 300 data records; cylinders below 30t are auto-reset and above 30t are manual-reset. It has peak hold, auto power-off and 10-segment line correction. The HC-L1 gauge uses a high-capacity rechargeable battery and the HC-L2 uses 3 AA batteries; continuous operation exceeds 200 hours.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| φd1 (mm) | 100kN: 27; 200kN: 35; 300kN: 45; 500kN: 60; 1000kN: 85 |
| φd2 (mm) | 100kN: 49; 200kN: 65; 300kN: 74; 500kN: 104; 1000kN: 148 |
| φd3 (mm) | 100kN: 81; 200kN: 116; 300kN: 125; 500kN: 160; 1000kN: 220 |
| h1 (mm) | 100kN: 180; 200kN: 210; 300kN: 210; 500kN: 220; 1000kN: 270 |
| h2 (mm) | 100kN: 11; 200kN: 11; 300kN: 11; 500kN: 11; 1000kN: 11 |
| Item | Specification |
| Data records | 300 entries; Chinese/English menu |
| Reset mode | ≤30t automatic reset; >30t manual reset |
| Gauge power supply | HC-L1 rechargeable battery; HC-L2 three AA batteries |
| Continuous working time | >200 hours |
| Oil circuits | HC-10/20/30 single circuit; HC-50/100 dual circuit |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the HC Series Anchor Bolt Pull-out Tester comply with?
A1: The HC Series Anchor Bolt Pull-out Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the HC Series Anchor Bolt Pull-out Tester be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.
Overview
The HC series HC Series Anchor Bolt Pull-out Tester is used for anchoring force testing of various anchors, steel bars and expansion bolts, and can also perform on-site pull-out testing of glass curtain walls. It features Chinese/English setting menu and 300 data records; cylinders below 30t are auto-reset and above 30t are manual-reset. It has peak hold, auto power-off and 10-segment line correction. The HC-L1 gauge uses a high-capacity rechargeable battery and the HC-L2 uses 3 AA batteries; continuous operation exceeds 200 hours.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| φd1 (mm) | 100kN: 27; 200kN: 35; 300kN: 45; 500kN: 60; 1000kN: 85 |
| φd2 (mm) | 100kN: 49; 200kN: 65; 300kN: 74; 500kN: 104; 1000kN: 148 |
| φd3 (mm) | 100kN: 81; 200kN: 116; 300kN: 125; 500kN: 160; 1000kN: 220 |
| h1 (mm) | 100kN: 180; 200kN: 210; 300kN: 210; 500kN: 220; 1000kN: 270 |
| h2 (mm) | 100kN: 11; 200kN: 11; 300kN: 11; 500kN: 11; 1000kN: 11 |
| Item | Specification |
| Data records | 300 entries; Chinese/English menu |
| Reset mode | ≤30t automatic reset; >30t manual reset |
| Gauge power supply | HC-L1 rechargeable battery; HC-L2 three AA batteries |
| Continuous working time | >200 hours |
| Oil circuits | HC-10/20/30 single circuit; HC-50/100 dual circuit |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the HC Series Anchor Bolt Pull-out Tester comply with?
A1: The HC Series Anchor Bolt Pull-out Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the HC Series Anchor Bolt Pull-out Tester be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.