MP Series Electronic Balance
  • MP Series Electronic Balance
0

MP Series Electronic Balance

MP series electronic balance with backlit LCD, vibration filtering, full-range tare and optional RS232 and under-hook weighing.

Overview

The MP series electronic balance offers fast weighing and high stability with a soft backlit LCD; an internal RS232 interface and built-in under-hook are optional. It features 4-level vibration filtering, adjustable weighing speed, full-range tare, auto zero tracking, auto calibration, self-diagnosis and overload protection, plus counting, percentage weighing, and g/oz/ct unit conversion.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Large LCD display showing real-time test parameters and results
• USB / RS232 data export to PC for further analysis
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Max capacity100 / 200 / 300 / 400 / 500g
Readability0.01g
ModelsMP2001 / MP6001 / MP10001 / MP12001
Max capacity200 / 600 / 1000 / 1200g
Readability0.1g
ModelsMP20D / MP2100 / MP31001 / MP51001 / MP61001
Max capacity2000 / 2100 / 3100 / 5100 / 6100g
Readability0.05g (MP20D); 0.1g (others)
Pan sizeφ100–φ125mm
Overall dimensions195×250×75mm

Standards

GB/T, JTG, ASTM

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the MP Series Electronic Balance comply with?

A1: The MP Series Electronic Balance is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the MP Series Electronic Balance be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.

Overview

The MP series electronic balance offers fast weighing and high stability with a soft backlit LCD; an internal RS232 interface and built-in under-hook are optional. It features 4-level vibration filtering, adjustable weighing speed, full-range tare, auto zero tracking, auto calibration, self-diagnosis and overload protection, plus counting, percentage weighing, and g/oz/ct unit conversion.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Large LCD display showing real-time test parameters and results
• USB / RS232 data export to PC for further analysis
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Max capacity100 / 200 / 300 / 400 / 500g
Readability0.01g
ModelsMP2001 / MP6001 / MP10001 / MP12001
Max capacity200 / 600 / 1000 / 1200g
Readability0.1g
ModelsMP20D / MP2100 / MP31001 / MP51001 / MP61001
Max capacity2000 / 2100 / 3100 / 5100 / 6100g
Readability0.05g (MP20D); 0.1g (others)
Pan sizeφ100–φ125mm
Overall dimensions195×250×75mm

Standards

GB/T, JTG, ASTM

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the MP Series Electronic Balance comply with?

A1: The MP Series Electronic Balance is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the MP Series Electronic Balance be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.