Curing cabinet with automatic temperature and humidity control for standard curing of cement and concrete specimens.
Overview
This curing box is developed according to GB1345-999 and technical materials from the National Academy of Building Research. It is used for standard temperature/humidity curing of concrete and cement specimens in medium/large factories, construction and bridge engineering, and research institutes. It has a thin-steel body with stainless steel inner chamber, and built-in heating, cooling, humidifying and circulating-air systems, featuring elegant appearance, high temperature accuracy and long service life.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• High measurement accuracy with stable repeatability
• Precision temperature control with PID regulation and over-temperature protection
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| Instrument accuracy | ±0.1℃ |
| Temp. difference | Type A ±1℃; Type B ±2℃ |
| Humidity | RH>92% (adjustable) |
| Power supply | AC220V |
| Heating power | 1000W |
| Cooling power | 150W |
| Humidifying power | 55W |
| Humidifying rate | 400mL/h |
| Humidifier tank | 5.5L |
| Fan | 220V 30W (40A); Type B has no fan |
| Effective volume | 550×740×1100mm |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the Standard Constant Temperature and Humidity Curing Cabinet comply with?
A1: The Standard Constant Temperature and Humidity Curing Cabinet is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the Standard Constant Temperature and Humidity Curing Cabinet be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.
Overview
This curing box is developed according to GB1345-999 and technical materials from the National Academy of Building Research. It is used for standard temperature/humidity curing of concrete and cement specimens in medium/large factories, construction and bridge engineering, and research institutes. It has a thin-steel body with stainless steel inner chamber, and built-in heating, cooling, humidifying and circulating-air systems, featuring elegant appearance, high temperature accuracy and long service life.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• High measurement accuracy with stable repeatability
• Precision temperature control with PID regulation and over-temperature protection
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| Instrument accuracy | ±0.1℃ |
| Temp. difference | Type A ±1℃; Type B ±2℃ |
| Humidity | RH>92% (adjustable) |
| Power supply | AC220V |
| Heating power | 1000W |
| Cooling power | 150W |
| Humidifying power | 55W |
| Humidifying rate | 400mL/h |
| Humidifier tank | 5.5L |
| Fan | 220V 30W (40A); Type B has no fan |
| Effective volume | 550×740×1100mm |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the Standard Constant Temperature and Humidity Curing Cabinet comply with?
A1: The Standard Constant Temperature and Humidity Curing Cabinet is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the Standard Constant Temperature and Humidity Curing Cabinet be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.
