ZBL-L1 pull-off tester for bond strength of tiles, coatings, plaster and insulation layers, with peak hold and data storage.
Overview
The ZBL-L1 ZBL-L1 Pull-off Adhesion Tester adopts an integrated design with embedded measurement display. It features peak hold, storage of up to about 8000 components, 10-segment line correction, auto power-off and backlight, built-in Li-ion battery with standard USB charging, resolution up to 0.001kN, USB and wireless data transmission, and a countdown function for observing the load-holding state. It is suitable for testing the bonding and tensile strength of exterior wall tiles, external wall insulation, fixing rivets, mosaic, mortar, small anchors, various boards and paints in construction engineering.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• Large LCD display showing real-time test parameters and results
• USB / RS232 data export to PC for further analysis
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| Maximum tensile force | 6kN |
| Tensile stroke | 60mm |
| Accuracy class | ±0.5%FS |
| Weight | 2.9kg |
| Power | built-in Li-ion battery |
| Resolution | 0.001kN |
| Storage | approx. 8000 components |
| Data transmission | USB / wireless |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the ZBL-L1 Pull-off Adhesion Tester comply with?
A1: The ZBL-L1 Pull-off Adhesion Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the ZBL-L1 Pull-off Adhesion Tester be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.
Overview
The ZBL-L1 ZBL-L1 Pull-off Adhesion Tester adopts an integrated design with embedded measurement display. It features peak hold, storage of up to about 8000 components, 10-segment line correction, auto power-off and backlight, built-in Li-ion battery with standard USB charging, resolution up to 0.001kN, USB and wireless data transmission, and a countdown function for observing the load-holding state. It is suitable for testing the bonding and tensile strength of exterior wall tiles, external wall insulation, fixing rivets, mosaic, mortar, small anchors, various boards and paints in construction engineering.
Applications
• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies
Features
• Large LCD display showing real-time test parameters and results
• USB / RS232 data export to PC for further analysis
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual
Technical Specifications
| Item | Specification |
| Maximum tensile force | 6kN |
| Tensile stroke | 60mm |
| Accuracy class | ±0.5%FS |
| Weight | 2.9kg |
| Power | built-in Li-ion battery |
| Resolution | 0.001kN |
| Storage | approx. 8000 components |
| Data transmission | USB / wireless |
Standards
GB/T, JTG, ASTM
Standard Delivery
• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit
FAQ
Q1: What standards does the ZBL-L1 Pull-off Adhesion Tester comply with?
A1: The ZBL-L1 Pull-off Adhesion Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.
Q2: How often should the ZBL-L1 Pull-off Adhesion Tester be calibrated?
A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.
Q3: What is the lead time and do you provide training?
A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.