JF-3 Limiting Oxygen Index (LOI) Tester
  • JF-3 Limiting Oxygen Index (LOI) Tester
0

JF-3 Limiting Oxygen Index (LOI) Tester

JF-3 limiting oxygen index tester measuring the minimum oxygen concentration for combustion of plastics, rubber, fibers and foams.

Overview

The LOI apparatus determines the minimum oxygen concentration (volume % O in an O/N mixture) required to support candle-like flaming combustion of a polymer (plastic, rubber, fibre, foam, wood, etc.) under defined conditions. It comprises a vertical control cabinet, a transparent quartz-glass combustion column, a gas mixer, O/N flow and pressure regulation, an oxygen sensor and a digital readout. The specimen is clamped vertically in the column in an upward co-current O/N flow; after ignition at the top, burn time or burn length is observed, and through a series of oxygen concentrations the lowest O level that sustains 3 min burning or 50 mm burn length is determined. Compliant with GB/T 2406.2 (ISO 4589-2, ASTM D 2863), it is widely used for flammability grading and flame-retardant formulation in plastics, rubber, textiles, building materials and electronics.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Principleoxygen-index candle-type flame combustion
StandardsGB/T 2406.2, ISO 4589-2, ASTM D 2863
O₂ display0–100% O₂, direct digital readout
Resolution±0.1%
Overall accuracyclass 0.4 (0.2 on some models)
Flow range0–10 L/min (60–600 L/h)
Response time<5 s
Combustion columnquartz glass, ID φ75 mm, L ~300–450 mm
Gas velocity in column40±10 mm/s
Mixerglass-bead packed O₂/N₂ mixer
O₂/N₂ inlet pressure>0.25 MPa
Pressure gauge accuracyclass 2.5
Specimenvertical centre mount in column
Criterionmin. O₂% sustaining 3 min or 50 mm burn

Standards

GB/T, JTG, ASTM

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the JF-3 Limiting Oxygen Index (LOI) Tester comply with?

A1: The JF-3 Limiting Oxygen Index (LOI) Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the JF-3 Limiting Oxygen Index (LOI) Tester be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.

Overview

The LOI apparatus determines the minimum oxygen concentration (volume % O in an O/N mixture) required to support candle-like flaming combustion of a polymer (plastic, rubber, fibre, foam, wood, etc.) under defined conditions. It comprises a vertical control cabinet, a transparent quartz-glass combustion column, a gas mixer, O/N flow and pressure regulation, an oxygen sensor and a digital readout. The specimen is clamped vertically in the column in an upward co-current O/N flow; after ignition at the top, burn time or burn length is observed, and through a series of oxygen concentrations the lowest O level that sustains 3 min burning or 50 mm burn length is determined. Compliant with GB/T 2406.2 (ISO 4589-2, ASTM D 2863), it is widely used for flammability grading and flame-retardant formulation in plastics, rubber, textiles, building materials and electronics.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Principleoxygen-index candle-type flame combustion
StandardsGB/T 2406.2, ISO 4589-2, ASTM D 2863
O₂ display0–100% O₂, direct digital readout
Resolution±0.1%
Overall accuracyclass 0.4 (0.2 on some models)
Flow range0–10 L/min (60–600 L/h)
Response time<5 s
Combustion columnquartz glass, ID φ75 mm, L ~300–450 mm
Gas velocity in column40±10 mm/s
Mixerglass-bead packed O₂/N₂ mixer
O₂/N₂ inlet pressure>0.25 MPa
Pressure gauge accuracyclass 2.5
Specimenvertical centre mount in column
Criterionmin. O₂% sustaining 3 min or 50 mm burn

Standards

GB/T, JTG, ASTM

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the JF-3 Limiting Oxygen Index (LOI) Tester comply with?

A1: The JF-3 Limiting Oxygen Index (LOI) Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the JF-3 Limiting Oxygen Index (LOI) Tester be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.