CIC-D160 Ion Chromatograph
  • CIC-D160 Ion Chromatograph
0

CIC-D160 Ion Chromatograph

CIC-D160 bench-top ion chromatograph with suppressor and conductivity detector for anions and cations in water and materials.

Overview

The CIC-D160 is a bench-top ion chromatograph comprising a high-pressure constant-flow pump, autosampler, forced-air column oven, suppressor and auto-range conductivity detector, capable of separating and quantifying multiple anions and cations in a single injection. All flow paths are PEEK, resistant to pH 0-14 eluents and reversed-phase solvents; a built-in electrochemical suppressor ensures high sensitivity and low background. It is widely used in environmental water analysis, food safety, pharmaceutical and chemical quality control laboratories.

Applications

• Environmental water and wastewater analysis laboratories
• Pharmaceutical and food safety quality control
• Chemical industry material testing
• Research and teaching laboratories

Features

• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Typebench-top ion chromatograph
Pumpdual-plunger high-pressure constant-flow, all PEEK
Flow range0.001–9.999 mL/min
Flow accuracy≤±0.1% (typical)
Max pressure0–35MPa, over-/under-pressure protection
Gradientup to 4 eluents
Wetted partsPEEK, pH 0–14
Eluent generatorbuilt-in EGC, KOH etc. on line
Eluent concentration0.1–100 mmol/L
Column ovenforced-air, RT+5 to 60°C
Temp. repeatability±0.2°C
Detectordual-temp auto-range conductivity
Conductivity range0–15000 μS/cm (up to 50000 optional)
Resolution≤0.002 μS/cm
Baseline noise≤0.002 μS/cm
Cell volume≤0.8 μL
SuppressorSHY-series chemically regenerated
ColumnsSH-series, smart-chip consumable tracking
Injection volumetypical 25 μL
Analytesanions/cations, organic acids, heavy metals

Standards

GB/T, ASTM, USP

Standard Delivery

• Main instrument unit
• Power cable / charger
• Operation manual
• Carrying case
• Calibration certificate

FAQ

Q1: What standards does the CIC-D160 Ion Chromatograph comply with?

A1: The CIC-D160 Ion Chromatograph is designed and manufactured in accordance with relevant Chinese national (GB) and industry standards, as well as applicable international standards. A calibration certificate is provided with each unit.

Q2: How often should the CIC-D160 Ion Chromatograph be calibrated?

A2: We recommend annual calibration by iRoad authorized technicians. For high-frequency use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. iRoad provides on-site installation and operator training for major equipment; remote video guidance is available for portable instruments.

Overview

The CIC-D160 is a bench-top ion chromatograph comprising a high-pressure constant-flow pump, autosampler, forced-air column oven, suppressor and auto-range conductivity detector, capable of separating and quantifying multiple anions and cations in a single injection. All flow paths are PEEK, resistant to pH 0-14 eluents and reversed-phase solvents; a built-in electrochemical suppressor ensures high sensitivity and low background. It is widely used in environmental water analysis, food safety, pharmaceutical and chemical quality control laboratories.

Applications

• Environmental water and wastewater analysis laboratories
• Pharmaceutical and food safety quality control
• Chemical industry material testing
• Research and teaching laboratories

Features

• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Typebench-top ion chromatograph
Pumpdual-plunger high-pressure constant-flow, all PEEK
Flow range0.001–9.999 mL/min
Flow accuracy≤±0.1% (typical)
Max pressure0–35MPa, over-/under-pressure protection
Gradientup to 4 eluents
Wetted partsPEEK, pH 0–14
Eluent generatorbuilt-in EGC, KOH etc. on line
Eluent concentration0.1–100 mmol/L
Column ovenforced-air, RT+5 to 60°C
Temp. repeatability±0.2°C
Detectordual-temp auto-range conductivity
Conductivity range0–15000 μS/cm (up to 50000 optional)
Resolution≤0.002 μS/cm
Baseline noise≤0.002 μS/cm
Cell volume≤0.8 μL
SuppressorSHY-series chemically regenerated
ColumnsSH-series, smart-chip consumable tracking
Injection volumetypical 25 μL
Analytesanions/cations, organic acids, heavy metals

Standards

GB/T, ASTM, USP

Standard Delivery

• Main instrument unit
• Power cable / charger
• Operation manual
• Carrying case
• Calibration certificate

FAQ

Q1: What standards does the CIC-D160 Ion Chromatograph comply with?

A1: The CIC-D160 Ion Chromatograph is designed and manufactured in accordance with relevant Chinese national (GB) and industry standards, as well as applicable international standards. A calibration certificate is provided with each unit.

Q2: How often should the CIC-D160 Ion Chromatograph be calibrated?

A2: We recommend annual calibration by iRoad authorized technicians. For high-frequency use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. iRoad provides on-site installation and operator training for major equipment; remote video guidance is available for portable instruments.