TT130 Ultrasonic Thickness Gauge
  • TT130 Ultrasonic Thickness Gauge
0

TT130 Ultrasonic Thickness Gauge

TT130 pulse-echo ultrasonic thickness gauge for wall thickness of metal plates, pipes and vessels from one side.

Overview

The TT130 TT130 Ultrasonic Thickness Gauge consists of a main unit and a probe. It works on the ultrasonic pulse-echo principle: pulsing electronics excite the probe, the sound wave travels through the material and is reflected by the back wall, then a microcontroller computes thickness from the known sound velocity and the round-trip time, displayed on the LCD. Microprocessor-controlled, it is accurate, compact, light and easy to operate; with a known sound velocity it non-destructively measures steel plate/pipe, cast iron, plastic, ceramic and glass. Widely used in petrochemical, power, boiler/pressure-vessel and pipeline wall-thickness corrosion inspection.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• High measurement accuracy with stable repeatability
• Large LCD display showing real-time test parameters and results
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Measuring range0.75–300.0mm (steel, probe-dependent)
Display resolution0.01mm
Sound velocity range1000–9999 m/s
Accuracy±(1%H+0.1)mm
Surface temperature-10 to 60°C
Min. pipeΦ20mm × 3.0mm wall
Probe5MHz / 10mm std; 6mm, 12mm optional
Calibration4.0mm steel block
Unitmm
Power2×AA 1.5V alkaline batteries
Weightapprox. 170g
Optional probes2.5MHz (3–300mm), 7MHz (0.75–60mm)
Materialsmetals, plastics, ceramics, glass
Standard setunit, 5MHz probe, 4.0mm block, batteries, couplant
Display4-digit LCD

Standards

GB/T 9444, ASTM A578, JGJ/T 203

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the TT130 Ultrasonic Thickness Gauge comply with?

A1: The TT130 Ultrasonic Thickness Gauge is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the TT130 Ultrasonic Thickness Gauge be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.

Overview

The TT130 TT130 Ultrasonic Thickness Gauge consists of a main unit and a probe. It works on the ultrasonic pulse-echo principle: pulsing electronics excite the probe, the sound wave travels through the material and is reflected by the back wall, then a microcontroller computes thickness from the known sound velocity and the round-trip time, displayed on the LCD. Microprocessor-controlled, it is accurate, compact, light and easy to operate; with a known sound velocity it non-destructively measures steel plate/pipe, cast iron, plastic, ceramic and glass. Widely used in petrochemical, power, boiler/pressure-vessel and pipeline wall-thickness corrosion inspection.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• High measurement accuracy with stable repeatability
• Large LCD display showing real-time test parameters and results
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Measuring range0.75–300.0mm (steel, probe-dependent)
Display resolution0.01mm
Sound velocity range1000–9999 m/s
Accuracy±(1%H+0.1)mm
Surface temperature-10 to 60°C
Min. pipeΦ20mm × 3.0mm wall
Probe5MHz / 10mm std; 6mm, 12mm optional
Calibration4.0mm steel block
Unitmm
Power2×AA 1.5V alkaline batteries
Weightapprox. 170g
Optional probes2.5MHz (3–300mm), 7MHz (0.75–60mm)
Materialsmetals, plastics, ceramics, glass
Standard setunit, 5MHz probe, 4.0mm block, batteries, couplant
Display4-digit LCD

Standards

GB/T 9444, ASTM A578, JGJ/T 203

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the TT130 Ultrasonic Thickness Gauge comply with?

A1: The TT130 Ultrasonic Thickness Gauge is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the TT130 Ultrasonic Thickness Gauge be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.