ZBL-U5100 Non-metallic Ultrasonic Tester
  • ZBL-U5100 Non-metallic Ultrasonic Tester
0

ZBL-U5100 Non-metallic Ultrasonic Tester

ZBL-U5100 ultrasonic tester for concrete defects, crack depth and strength by ultrasonic-rebound method, IP65 rated.

Overview

The ZBL-U5100 ZBL-U5100 Non-metallic Ultrasonic Tester is feature-complete, stable and cost-effective, with high-power transmission and ultra-low reception noise. Its double-injection transparent waterproof design reaches IP65 protection. The transflective high-brightness TFT color LCD is clearly readable in sunlight; it can import digital rebound hammer data for ultrasonic-rebound combined method processing. It is used for structural concrete compressive strength, crack depth and defect detection, ultrasonic transmission testing of pile and diaphragm wall integrity, geological survey, rock mass integrity and weathering evaluation, and mechanical property testing of non-metallic materials.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Large LCD display showing real-time test parameters and results
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Main controlbuilt-in A8 industrial control board
Display5.7" high-brightness TFT color LCD
Operationkeys + touchscreen
Storageinternal 256M + large-capacity USB flash drive
Acquisition modedual channel
Triggersignal trigger
Sampling interval0.05–400μs, 14 gears adjustable
Time-base accuracy0.05μs
Dynamic range130dB
Bandwidth10–250kHz
Gain accuracy0.5dB
Transmit voltage65/125/250/500/1000V, 5 gears adjustable
Communicationstandard USB
Working time≥6h
PowerLi-ion battery
Operating temp.0–40℃; humidity<90%
Host dimensions250×185×58mm; weight 1.8kg

Standards

GB/T 9444, ASTM A578, JGJ/T 203

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the ZBL-U5100 Non-metallic Ultrasonic Tester comply with?

A1: The ZBL-U5100 Non-metallic Ultrasonic Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the ZBL-U5100 Non-metallic Ultrasonic Tester be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.

Overview

The ZBL-U5100 ZBL-U5100 Non-metallic Ultrasonic Tester is feature-complete, stable and cost-effective, with high-power transmission and ultra-low reception noise. Its double-injection transparent waterproof design reaches IP65 protection. The transflective high-brightness TFT color LCD is clearly readable in sunlight; it can import digital rebound hammer data for ultrasonic-rebound combined method processing. It is used for structural concrete compressive strength, crack depth and defect detection, ultrasonic transmission testing of pile and diaphragm wall integrity, geological survey, rock mass integrity and weathering evaluation, and mechanical property testing of non-metallic materials.

Applications

• Road and highway engineering laboratory testing
• Construction material quality control and acceptance
• Research and teaching laboratories
• Third-party inspection and certification bodies

Features

• Large LCD display showing real-time test parameters and results
• Robust construction suitable for both laboratory and field use
• Compliant with relevant Chinese and international testing standards
• Complete with calibration certificate and operation manual

Technical Specifications

ItemSpecification
Main controlbuilt-in A8 industrial control board
Display5.7" high-brightness TFT color LCD
Operationkeys + touchscreen
Storageinternal 256M + large-capacity USB flash drive
Acquisition modedual channel
Triggersignal trigger
Sampling interval0.05–400μs, 14 gears adjustable
Time-base accuracy0.05μs
Dynamic range130dB
Bandwidth10–250kHz
Gain accuracy0.5dB
Transmit voltage65/125/250/500/1000V, 5 gears adjustable
Communicationstandard USB
Working time≥6h
PowerLi-ion battery
Operating temp.0–40℃; humidity<90%
Host dimensions250×185×58mm; weight 1.8kg

Standards

GB/T 9444, ASTM A578, JGJ/T 203

Standard Delivery

• Main instrument unit
• Power cable
• Operation manual
• Spare parts kit

FAQ

Q1: What standards does the ZBL-U5100 Non-metallic Ultrasonic Tester comply with?

A1: The ZBL-U5100 Non-metallic Ultrasonic Tester is designed and manufactured in accordance with relevant Chinese national (GB) and transport industry (JTG) standards, as well as applicable ASTM and AASHTO international standards. A calibration certificate traceable to national standards is provided with each unit.

Q2: How often should the ZBL-U5100 Non-metallic Ultrasonic Tester be calibrated?

A2: We recommend annual calibration by authorized technicians or by iRoad after-sales service center. For high-frequency laboratory use, semi-annual calibration is advised. The instrument is supplied with a factory calibration certificate.

Q3: What is the lead time and do you provide training?

A3: Standard units are usually shipped within 7-15 working days. Custom configurations may require 20-30 days. iRoad provides on-site installation, commissioning and operator training for major equipment; remote video guidance is available for standard laboratory instruments.